There is a strengthened school building in Ercis. This is a 4-story RC frame with original and added shear walls. Non-structural damage is moderate. Original frame of the structure have bad quality concrete and workmanship. Original shear walls of the structure along the north-south direction has honeycomb shear cracks in the first three stories with decreasing intensity. Cracks at the base are about a mm wide. Added shear walls for strengthening along the north-south direction show signs of separations at the upper beam and column interfaces for the lower two stories.

4-story school building that is strengthened for earthquake demand

Honeycomb shear cracks at the existing shear wall.

Separation cracks at the added shear wall-existing frame interfaces